output power
output voltage v1
output current v1
standby supply v2 model number
nominal peak(1) nominal peak(1)
250 w 300 w 12.0 v 20.8 a 25.00 a 5.0 v/0.5 a ccb250ps12
250 w 300 w 15.0 v 16.7 a 20.00 a 5.0 v/0.5 a ccb250ps15
250 w 300 w 24.0 v 10.4 a 12.50 a 5.0 v/0.5 a ccb250ps24
250 w 300 w 28.0 v 8.9 a 10.70 a 5.0 v/0.5 a ccb250ps28
250 w 300 w 36.0 v 6.9 a 8.30 a 5.0 v/0.5 a ccb250ps36
250 w 300 w 48.0 v 5.2 a 6.25 a 5.0 v/0.5 a ccb250ps48
input voltage ? 80-275 vac (see derating curve)
input frequency ? 47-63 hz
input current ? 2.4 a typical at 115 vac, full load
1.2 a typical at 230 vac, full load
inrush current ? 30 a max at 230 vac, cold start at 25 °c
power factor ? >0.9
earth leakage current ? 250 μa max at 264 vac/60 hz, typically
60/110 μa, 115/230 vac
patient leakage current ? 100 μa max, 264 vac 60 hz
input protection ? internal t5.0 a/250 v fuse in line
and neutral
output
output voltage ? 12-48 vdc (see tables)
output voltage trim ? ±3% (see mechanical details)
initial set accuracy ? ±0.5% v1, ±5% v2
minimum load ? no minimum load required
start up delay ? 1 s typical
start up rise time ? 0.5 s typical
hold up time ? 16 ms min at 90 vac
drift ? ±0.2% after 20 min warm up
line regulation ? ±0.5% max
load regulation ? ±1% v1, ±5% v2
over/undershoot ? 5% max
transient response ? 4% max. deviation, recovery to within
1% in 500 μs for a 50-75-50% load
change
ripple & noise ? 1% pk-pk, 20 mhz bandwidth
overvoltage protection ? 115-140% vnom, recycle input to reset
(v1 only)
overload protection ? 125-165% inom v1 only
short circuit protection ? continuous trip and restart (hiccup mode)
temperature ? 0.05%/°c
coefficient
remote on/off ? uncommitted isolated optocoupler diode,
(inhibit/enable) powered diode inhibits v1
xp
general
efficiency ? up to 95%
isolation ? 4000 vac input to output 2 x mopp,
1500 vac input to ground 1 x mopp,
1500 vac output to ground 1 x mopp
switching frequency ? pfc 30-500 khz, boost 25.6 khz,
main 51.2 khz
signals ? power fail
inhibit, 5 v standby
mtbf ? 369 khrs to mil-hdbk-217f at 25 °c, gb
environmental
operating temperature ? -20 °c to +70 °c derate linearly from
+50 °c at 2.5%/?c to 50% load at +70 °c.
see derating curve & longform datasheet
cooling ? convection cooled
operating humidity ? 95% rh, non-condensing
storage temperature ? -40 °c to +85 °c
operating altitude ? 3000 m
shock ? 30 g pk, half sine, 6 axes
vibration ? 2 g rms, 5 hz to 500 khz, 3 axes
emc & safety
low voltage psu emc ? en61204-3, high severity level
emissions ? en55011/22 level b conducted
en55011/22 level a radiated
harmonic currents ? en61000-3-2, class a
voltage flicker ? en61000-3-3
radiated immunity ? en61000-4-3, level 3 perf criteria a
eft/burst ? en61000-4-4, level 3 perf criteria a
surge ? en61000-4-5, installation class 3
perf criteria a
conducted immunity ? en61000-4-6, level 3 perf criteria a
dips & interruptions ? en61000-4-11, 30% 10 ms, 60% 100 ms,
5000 ms, perf criteria a, b, b,
en60601-1-2, 30% 500 ms, 60% 100 ms,
10 ms, 5000 ms, perf criteria
a, a, a, b - 230 vac. consult longform
datasheet for 115 v operation.
safety approvals ? iec60950-1 cb report, ul60950-1, tuv
en60950-1, iec60601-1 cb report,
ul60601-1, tuv 60601-1,
equipment protection ? en60601-1, ansi/aami es60601-1,
class csa22.2 no.60601-1 per cul bf rated,
including risk management, en60950,
ul60950